Combined smoke and heat testing

A119-YW Smoke & Heat Detector Tester Family

Portable combined testers for functional response checks of compatible smoke and heat detectors during commissioning, scheduled inspection and maintenance.

The blue product shown is the metal A119-YWS01 configuration supplied in the current product image.

Wanlin A119-YWS01 blue metal smoke and heat detector tester

Verified product configurations

Choose the exact suffix before ordering.

A119-YW is the combined smoke-and-heat family. The supplied manuals identify two materially different configurations; their electrical and mechanical data must not be mixed.

A119-YW02

Flame-retardant ABS smoke + heat tester

A separate black configuration documented in the newer YW02 manual.

  • Flame-retardant ABS body
  • 3.7 V, 2600 mAh battery
  • 5 V / 2 A charging
  • Output temperature above 70°C
  • Over 300 smoke tests or over 200 heat tests per full charge
  • 58 cm telescopic pole, extending to 3 m
Download YW02 Chinese manual

Configuration control: confirm the full model suffix, working height, battery, pole, accessories and manual revision on the quotation. The YWS01 and YW02 values are not interchangeable.

Manual-based comparison

Verified technical data.

Values below are taken from the supplied Chinese manuals. They describe the documented configurations, not every possible OEM order.

ItemA119-YWS01 metalA119-YW02 ABS
Test functionsSmoke simulation + heated airSmoke simulation + heated air
Battery7.4 V / 3000 mAh3.7 V / 2600 mAh
Charger5 V / 2 A, USB Type-C5 V / 2 A, USB Type-C
Output temperatureAbove 70°CAbove 70°C
Documented full-charge capacityStandard: >300 smoke tests; >200 heat tests>300 smoke tests; >200 heat tests
HousingAviation aluminumFlame-retardant ABS
Tester head295 mm225 × 105 mm
Pole / working reach3 m standard/Pro; 4 m Max58 cm retracted; up to 3 m extended
Complete set weight3.7 kg including case2 kg including case
Document revisionV1.1, 8 May 202628 February 2026

Operating sequence

Position upright. Select mode. Trigger the sensor.

Use only after reading the exact supplied manual and the detector manufacturer's test instructions.

1

Prepare

Confirm battery charge, approved smoke fluid, detector compatibility, pole connection and a secure work area.

2

Select the function

Choose smoke, heated-air or air-blow mode. Indicator colors identify the selected and active state.

3

Trigger and verify

Bring the infrared sensor into the trigger area, apply the stimulus, verify detector response and record the result.

Safety information

Important instructions from the manuals.

Keep the tester upright

During smoke operation, keep the head upward and do not block the air inlet. Incorrect orientation can dry-burn and damage the heating components.

Use the specified smoke fluid

Maintain sufficient fluid and use the manufacturer-matched product. Do not operate near flammable gas or in strong direct sunlight.

Avoid hot surfaces

Do not touch the high-temperature area during heat testing. Allow the unit to cool and keep it dry after use.

Inspect before elevation

Check the tester head, extension-pole joints and battery state before raising the tool to ceiling level.

A functional response test does not replace detector calibration, laboratory conformity testing, system commissioning or the complete inspection procedure required by the site or authority.

Standard / Pro / Max

YWS01 version differences documented in the manual.

YWS01 versionBatterySmoke testsApprox. heating ratePoleColor
Standard7.4 V / 3000 mAh>3001°C/s3 mRed
Pro7.4 V / 3200 mAh>3501.5°C/s3 mBlue
Max7.4 V / 3500 mAh>4002°C/s4 mGold

Version values are reproduced from the supplied YWS01 V1.1 manual and should be reconfirmed against the current quotation before purchase.

A119-YW questions

Frequently asked technical questions.

These answers define the product family and the limits of the available documents.

What is the A119-YW smoke and heat detector tester?

The A119-YW is a Wanlin product family combining smoke simulation and heated-air functions for functional response checks of compatible smoke and heat detectors.

What is the difference between A119-YWS01 and A119-YW02?

A119-YWS01 is the aviation-aluminum configuration with a 7.4 V battery platform. A119-YW02 is a separate flame-retardant ABS configuration using a 3.7 V battery platform. Their specifications must not be mixed.

How high can the A119-YW detector tester reach?

The supplied YWS01 manual documents 3 m Standard and Pro poles and a 4 m Max pole. The YW02 manual documents a 58 cm telescopic pole extending to 3 m.

Does an A119-YW test prove detector compliance?

No. It provides a functional response check and does not replace calibration, laboratory conformity testing, system commissioning or the complete inspection procedure required for the site.

Which manual should be used?

Use the manual matching the full supplied suffix, housing, battery and pole configuration. Confirm the exact model and current document revision on the quotation.

Technical content last reviewed against the supplied manuals on 9 November 2026.

Export enquiry

Request the exact A119-YW configuration.

Send the detector types, working height, quantity, destination market and preferred housing. We will confirm the suffix, accessories and current document set.

Request a Quote